Choose a 10-inch open-frame desktop rack if you have desk space and want easy access to your gear and cables. Choose a lockable steel wall cabinet if you want the gear off the desk and behind a locked door. DeskPi desktop rack, Lanberg open rack, Lanberg wall cabinet
Open desktop racks and lockable wall cabinets
All three models use 10-inch mounting. Depth figures below use each manufacturer’s published terms.
| Model | Good fit when | Rack space | Published depth |
|---|---|---|---|
| DeskPi RackMate T0 (DP-0047) | You want an open desktop rack and 4U is enough. | 4U | 200 mm internal, 200 mm outside. DeskPi specifications |
| Lanberg OR10-2306-B | You want an open frame with four vertical rails and the option to use a countertop or wall. | 6U | 300 mm working, 300 mm outside. Lanberg open-rack specifications |
| Lanberg WF10-2306-00S | You want a wall cabinet with a steel body and a lockable metal door. | 6U | 238 mm working, 310 mm outside. Lanberg cabinet specifications |
Check fit before you buy
- Count rack units. Add up the vertical space your equipment and accessories will occupy. Allow room for the device on its shelf. In a hypothetical layout, a 1U patch panel, a 1U switch, and a shelf-and-device combination occupying 2U fill a 4U rack. DeskPi rack layout guide
- Check the mounting hardware. Confirm that the device’s brackets or shelf are made for 10-inch mounting. The open Lanberg has four vertical rails, and the lockable cabinet has two. Lanberg open rack, Lanberg wall cabinet
- Compare usable depths. Check your required depth against the rack’s published working or internal depth. DeskPi specifications, Lanberg open rack, Lanberg wall cabinet
Worked example. Suppose a device needs 225 mm behind its mounting face and its connected cables need another 20 mm. The total is 245 mm. That exceeds the Lanberg wall cabinet’s 238 mm working depth, even though the cabinet is 310 mm deep outside. The open Lanberg’s 300 mm working depth clears this first check. Lanberg wall cabinet, Lanberg open rack
Check the wall location
- Check the cabinet load and the wall. Add up the equipment and accessories and compare their weight with the cabinet’s load limit. For the WF10-2306-00S, Lanberg lists a 20 kg maximum static load and a 5.45 kg empty cabinet. For wall mounting, see the Quick Guide under Download files. Lanberg cabinet specifications
- Check access and ventilation. At the proposed location, check for space around the cabinet’s front door and top ventilation opening. The Lanberg wall cabinet has one fan position. Lanberg cabinet specifications
Evidence and limits. This comparison uses DeskPi’s DP-0047 and Lanberg’s OR10-2306-B and WF10-2306-00S product documentation, plus DeskPi’s layout guide. Documentation was checked on November 27, 2026. No racks were installed or tested for this guide.